Underground power-cable fault location

Cable Fault Test Van Malaysia: TBS-1000 and Custom Fault Location Solutions

We supply the vehicle-ready TANBOS TBS-1000 in Malaysia and configure cable fault testing around your network, likely faults and field vehicle. The system handles DC testing and fault pre-location, while surface pinpointing, cable identification and VLF commissioning require tools specified for the job.

WhatsApp Innovam about a cable fault test van

Tell us the cable voltage class, likely fault behaviour, vehicle type, required test functions and Malaysia project location.

  • 8, 16 and 32 kV surge selections
  • Wireless tablet control
  • Emergency stop and earthing detection
Vehicle-mounted TBS-1000 cable fault system with a technician using its control tablet
The equipment sits in the vehicle while the operator uses the wireless tablet beside it.

Equipment selection

What equipment can Innovam match to your cable fault workflow?

Start with the vehicle-ready core. Specify pinpointing, cable identification, fault conversion and commissioning tools separately as the work requires.

TBS-1000 system installed in a vehicle

Vehicle-ready core

TBS-1000 Cable Test Van

For crews that want a vehicle-mounted cable fault system, the TBS-1000 combines TDR, ARM, ICE and DECAY pre-location with surge and DC testing. It can also deploy as a mobile unit. We review the network, vehicle and accessories before defining the installation and supply scope.

T32 portable cable fault location equipment

Portable alternative

T32 Portable Cable Fault Location System

The T32 suits crews that move equipment between vehicles or sites. Its surge generator, TDR pre-locator and PP20 pinpointer travel separately and can operate independently. We can compare this setup with a vehicle installation.

View the T32 portable system
LB4-60A bridge and burn-through unit

Difficult fault support

LB4-60A 2-in-1 Smart Bridge and Burnthrough

This separate unit provides bridge measurement and burn-through for relevant high-resistance faults. We assess the fault conditions before specifying either method.

View the LB4-60A bridge and burn-through unit
HCI de-energised cable identification equipment

Target cable confirmation

HCI Cable Identifier for De-energised Cables

This separate identifier helps confirm the intended cable in a dense bundle after authorised personnel establish electrical isolation under site procedures.

View the HCI cable identifier
VLF-90 portable cable withstand test system

Insulation and commissioning tests

VLF-90 Portable Hipot Test System

The VLF-90 handles very-low-frequency insulation withstand testing. We can scope it separately for projects that require a VLF commissioning test alongside fault location.

View the VLF-90 withstand test system

If you’re deciding which instruments to specify, discuss your configuration with us on WhatsApp.

Field workflow

What does the TBS-1000 do before a fault is excavated?

It helps test the cable and estimate fault distance. The crew verifies the target cable and narrows the surface location with compatible field equipment.

  1. Confirm the cable and test setup

    Authorised personnel establish cable identity, verify isolation and confirm the safe test setup under site procedures.

  2. Estimate the fault distance

    Assess fault behaviour and use TDR pre-location or, where appropriate, ARM, ICE or DECAY.

    Operator using the TBS-1000 control tablet inside a vehicle
    TBS-1000 tablet control in a vehicle-based setup.
  3. Pinpoint along the route

    Follow the cable route and use a compatible surge setup and acoustic-magnetic receiver to narrow the surface location.

  4. Verify before excavation

    Confirm the target and proposed excavation point under site procedures, then record the findings.

High-resistance or water-ingress faults can produce unclear TDR traces, so the crew may need another pre-location method or a bridge and burn-through assessment. We use our experience with these conditions to train operators in method selection.

Deployment comparison

Vehicle-ready TBS-1000 or portable system: which fits your team?

Choose by response frequency, available vehicle space and power, and how much the crew benefits from a permanently organised setup.

Decision TBS-1000 T32
Deployment TBS-1000 Integrated system for a suitable vehicle or mobile deployment. T32 Modular equipment for transport between jobs.
Fault-location methods TBS-1000 Built-in TDR, ARM, ICE and DECAY, plus DC and surge functions. T32 Supports low-voltage TDR, ARM and ICE, with PP20 for pinpointing.
Equipment and accessories TBS-1000 Confirm the installation, reels and pinpointing equipment in the quotation. T32 Plan how to carry and organise the three portable components.
Training and operation TBS-1000 Train on the integrated tablet controls. T32 Train on each instrument and how they work together.

Specify vehicle supply, VLF testing and cable identification separately for either setup. We can review your vehicle, equipment layout and service routine before recommending a system.

Custom van configuration

What must be defined in a custom cable fault test van configuration?

Agree a written scope for the vehicle, installed equipment and field accessories. Ask for a current technical schedule for the selected configuration before ordering.

Decision Why it matters How Innovam can help
Cable network and faults Why it matters Cable class and fault behaviour guide method choice. How we help Review likely faults and suitable test methods.
Vehicle and space Why it matters The platform and available space shape the layout. How we help Discuss installation layout, reels and equipment storage.
Field power and access Why it matters Power, earthing and safe access affect deployment. How we help Review field requirements with your site team.
Deliverables and operator skills Why it matters Records and crew experience shape commissioning and training. How we help Agree on handover checks and practical training.

Confirm which reels, pinpointer, bridge and burn-through equipment, cable identifier or VLF tester the quotation covers.

Deployment and field training

How does Innovam support deployment and operation in Malaysia?

We support application review, demonstration, supply, commissioning, field training and after-sales technical enquiries. We can discuss arrangements for Kuala Lumpur, Selangor, elsewhere in Peninsular Malaysia, Sabah and Sarawak.

Application and configuration review

We check the network and vehicle requirements so you can scope the equipment around the faults your crews encounter.

Demonstration and commissioning

We demonstrate the selected method and check the commissioned setup against the agreed scope.

Hands-on field training and support

We train technicians on the relevant TDR, surge and pinpointing workflow and discuss calibration, service or repair where applicable.

Operator using a pinpointer near a TBS-1000 vehicle
TBS-1000 system shown in a field demonstration setting.

Choosing the right scope

Why discuss a cable fault test van with Innovam?

We match fault behaviour, vehicle setup and crew workflow so you can agree on the configuration and support before delivery.

  • Method choice. We draw on experience with high-resistance, very-high-resistance and water-ingress faults to identify which methods are worth evaluating.
  • Deployment options. We compare integrated and portable setups so you can decide whether a vehicle installation fits your response routine.
  • Local support. We review demonstration, commissioning, training and applicable after-sales support so your team can plan the handover.

Before you specify the system

Cable fault test van FAQs

Does “TBS-1000 Cable Test Van” include a vehicle?

The TBS-1000 is a vehicle-ready system. We can review your intended platform and agree separately on vehicle supply or installation.

Does TDR alone identify the exact excavation point?

TDR and high-voltage pre-location methods estimate fault distance. A compatible surge setup and acoustic-magnetic pinpointer narrow the surface location. We can demonstrate both stages.

Can the system handle high-resistance or water-ingress faults?

The TBS-1000 offers several pre-location methods. We assess the cable and fault behaviour before recommending a method and can discuss a separate LB4-60A bridge or burn-through assessment where appropriate.

Is VLF-90 or cable identification part of every van?

VLF-90 and HCI are separate instruments. We can specify either in the quotation when the project calls for VLF withstand testing or identification of de-energised cables.

Can Innovam provide demonstrations, commissioning and training in Malaysia?

Yes. Share your project location, application and selected equipment so we can discuss suitable demonstration, commissioning and training arrangements.

Discuss your application

Specify the setup your cable network needs

Your cable network, fault methods, vehicle and crew workflow define the setup. We can scope the TBS-1000, a custom van solution or a portable alternative and support commissioning and training.

Share your cable voltage class, known fault behaviour, vehicle type, testing and identification needs, and project location in Malaysia.

WhatsApp Innovam about a cable fault test van
Topics