Test cable
Output line for the bridge ranging function.


Cable Fault System
Highly Accurate High-voltage Bridge for Cable Fault Pre-location
Cable Fault Location System
Go to Our Services >>Introduction
Introducing LB4-60A, a highly accurate high-voltage bridge designed to pre-locate cable faults. It is engineered to help find faults efficiently through smart technology, integrating intelligent diagnosis, bridge measurement, cross-section measurement and burnthrough functions in one compact system.
Output line for the bridge ranging function.

Used for the burn-through function.

Short-circuits the cable end during distance testing.

Grounds the equipment housing.

Supports regular calibration of the bridge fault location function.

Used to discharge the cable.

Supplies power to the device.

Grounding wire for the discharge rod.

Hook attachment for the discharge rod.

Illustration of the cable burn-through process.

Key Applications
With its single rotary knob, all functions can be selected and controlled easily.

No need to analyse waveforms or perform complicated calculations. The system displays the distance between you and the fault directly.

Up to 60kV output voltage makes it easier to burn high-resistive faults into low-resistive faults in a short time.

Intelligent diagnostic technology helps determine the fault type, recommends the test method and guides the operator into burnthrough or ranging mode.

Product Model
.jpg)
| Test Mode | Intelligent diagnosis mode, bridge mode, cross-section mode, burnthrough mode |
|---|---|
| Intelligent Diagnostic Mode | |
| Function | Automatically determines the fault type, recommends the test method and guides the operator into burnthrough mode or ranging mode |
| Output Voltage | 0–60kV DC, negative polarity |
| Burnthrough Mode | |
| Output Voltage | 0–60kV DC, negative polarity |
| Short Circuit Current | 400mA |
| Burnthrough Power | 20–100%, adjustable |
| Burnthrough Time | 0–90min, adjustable |
| Bridge Mode | |
| Output Voltage | 0–4kV DC, bipolarity |
| Output Current | 750mA |
| Cross-section Mode | |
| Cable Cross-sectional Area | 1–9999mm², adjustable |
| Boost Operation | CNC operation, automatic boost |
| Test Range | 0.001–50km |
| U-t, I-t Change Relationship | Two-dimensional coordinate map display |
| Voltage and Current Display | Digital display, no dashboard |
| Positioning Accuracy | ± (0.1% × L + 1)m, where L is the full cable length |
| Grounding Detection | Contact resistance between test ground and protection ground should be less than 10Ω |
| Safety | Temperature detection, automatic protection loop, double grounding system |
| Screen | 320 × 240 LCD, visible in sunlight |
| Data Storage | Records historical data in ranging mode, maximum 100 records |
| Maximum Output Power | 400W |
| Memory | 32G, USB port |
| Operating Temperature | -25°C to 50°C |
| Storage Temperature | -30°C to 60°C |
| Humidity | <95%, no condensation |
| Power Supply | AC 100V–240V, 50/60Hz |
| IP Rating | IP43 |
| Weight | 22.3kg without accessories |
| Dimensions (L × W × H) | 300 × 460 × 500mm |
Watch in Action