Civil & Land Surveying
Prevent utility strikes, locate hidden services and create more accurate underground maps before excavation.
Industry-focused solutions for underground utility detection, cable fault locating, thermal inspection and condition monitoring.
Start with your industry, understand the operational problem, then follow the recommended workflow and product.
Prevent utility strikes, locate hidden services and create more accurate underground maps before excavation.
Pinpoint cable faults, reduce outage time and identify thermal or acoustic warning signs before failure.
Track pipelines, detect pressurised leaks and monitor critical equipment in demanding environments.
Use the filters to preview how customers can discover the right solution by problem.
Unknown utility routes increase excavation risk, delays and costly service strikes.
Outdated records reduce confidence when planning new construction and maintenance.
Slow fault location prolongs outages and increases unnecessary excavation.
Overheating switchgear and transformers can escalate into avoidable failures.
Small leaks are difficult to locate but can create major safety and efficiency risks.
Long-distance metallic pipelines require reliable locating in harsh conditions.
Tell our team about your site conditions, operational challenge and preferred workflow.
Land surveying and subsurface utility engineering demand precision. Unmapped utility lines can cause project delays, safety hazards and major financial liabilities, while non-metallic utilities remain difficult to detect in challenging ground conditions.
Explore cable locating workflows and products tailored to each surveying application

The Challenge Tracing multiple lines across a site typically requires engineers to constantly walk back and forth between the transmitter and receiver to recalibrate the signal, draining productivity and increasing labour costs.
Our Solution The MSL-800 allows operators to pre-calibrate signals for up to 20 different cables at the source. The receiver then automatically identifies the pre-calibrated signal, drastically reducing round-trip calibration time and maximising fieldwork efficiency.

.png)
The Challenge Cutting into a live power line because it was mistaken for a decommissioned or communication cable is a catastrophic safety and financial risk.
Our Solution Equipped with a flexible current clamp (designed as a Rogowski coil), the MSL-800 safely identifies both energised and de-energised cables allowing for non-contact measurement of cables up to ∅200mm without disconnecting the line.
.png)
.png)
The Challenge Distorted electromagnetic fields near bends, tees, or close parallel utilities frequently cause standard locators to miscalculate the true depth of a buried asset.
Our Solution The MSL-800 utilises advanced digital filtering and multi-antenna array technology to filter out distorted field signals, providing reliable, real-time depth readings.
.png)

The Challenge Non-pressurised plastic pipes outfitted with tracer wires often suffer from poor grounding or weak signal transmission, making them virtually untraceable over long distances.
Our Solution The MSL-800 features high-output, adjustable transmitter frequencies that optimise signal induction on poorly conductive or insulated tracer wires.


The Challenge Standard electromagnetic locators require a conductive material to trace a line. As modern infrastructure increasingly utilises HDPE, PVC, and fibre-optic, field crews are left with dangerous blind spots especially in difficult conditions like saturated, high-clay soils.
Our Solution The Innovam Dual Sense can be used to detect these non-metallic materials directly, acting as the perfect complement to your existing EM and GPR.


The Challenge High moisture content and conductive clay compositions heavily absorb or scatter radar and electromagnetic pulses, causing severe signal loss and preventing accurate depth estimation.
Our SolutionThe Dual Sense is engineered with optimised multi-frequency ground penetration capabilities that cut through challenging soil profiles where conventional systems fail. It doesn't just push a signal into the ground; it intelligently reads the terrain to bypass dense interference. By delivering clear, uncompromising spatial data regardless of the soil matrix, the Dual Sense empowers field teams to locate, measure, and map infrastructure with absolute certainty.
.png)

Urban mapping projects often require scanning directly beneath thick asphalt or reinforced concrete. Standard tools struggle to differentiate between structural layers, rebar, and subsurface voids.
Our Solution The Dual Sense can pinpoint the exact location of the utility without having to push a GPR cart.

Our team can match your assets, inspection distance and reporting needs to an appropriate FOTRIC model.
Thermal and acoustic inspection helps utility teams identify abnormal conditions across transmission, substations and distribution assets without interrupting normal operation.
Explore the recommended FOTRIC inspection workflow and related product for each application.
Content direction and imagery adapted from FOTRIC’s official industry solution page .

Stable power distribution depends on routine inspection of electrical assets. A combined acoustic and thermal workflow helps maintenance teams identify developing problems from a safer distance and organise predictive maintenance before reliability is affected.


Acoustic imaging provides a fast, non-contact way to locate partial-discharge sources in substations, power plants and industrial electrical systems. Real-time visualisation helps teams recognise insulation problems earlier, including in noisy environments.


Thermal inspection supports predictive maintenance by revealing overheating components, connection problems and abnormal temperature patterns before they develop into equipment failure or unplanned downtime.

Our team can match your assets, inspection distance and reporting needs to an appropriate FOTRIC model.
Thermal inspection helps maintenance teams identify abnormal conditions in pumps, pipelines, electrical cables and insulated equipment before they threaten safe and continuous production.
Explore the recommended FOTRIC inspection workflow and related product for each application.
Content direction and imagery adapted from FOTRIC’s official industry solution page .

Centrifugal pumps are essential to continuous oil extraction. Contactless thermal monitoring helps operators recognise developing temperature abnormalities and evaluate pump condition while production equipment remains in service.


Ageing pipelines and worn electrical cables can create leakage and overheating risks. Thermal imaging helps teams locate suspicious temperature patterns so risky sections can be investigated and repaired before they contribute to a shutdown.

Our team can match your assets, inspection distance and reporting needs to an appropriate FOTRIC model.
Preview the direct product destination customers reach from each solution detail page.
Interactive gallery dropdown based on PDF page 13.
Field application
Inspection workflow
Operational environment
Cable and metallic utility locating with pre-calibrated signal recognition, digital filtering and multi-antenna depth measurement.
View ProductA complementary locating workflow for non-metallic pipe and underground utility detection.
View ProductDiagnostic equipment for cable path tracing, fault pinpointing and outage response.
View ProductA mobile integrated cable fault locating system designed to reduce transport and setup challenges at remote sites.
View Product
10kV and 12kV high-voltage insulation testers for cables, switchgear, arresters, motors, generators and transformers.
View Product
A single-core cable fault locating system that identifies the fault type, recommends Bridge or Burn-through mode and provides a digital fault-distance readout.
View Product
Portable 0.1Hz very-low-frequency withstand testing for high-capacitance power cables. Supplied field image model requires confirmation.
View ProductA combined acoustic and thermal inspection platform for predictive electrical maintenance.
View ProductNon-contact acoustic imaging for locating partial-discharge sources in high-voltage environments.
View ProductProfessional real-time thermal analysis for substations and critical electrical equipment.
View ProductContactless thermal monitoring for pumps and rotating equipment used during oil extraction.
View ProductThermal inspection for pipelines, electrical cables and equipment in oil and gas facilities.
View ProductCalibration, repair, technical support and training delivered through a clear service workflow.
Innovam supports customers beyond product purchase through calibration, repair, technical assistance and practical training.
Select a service to review the complete step-by-step process and prepare the right information before contacting our support team.
Routine calibration keeps multi-frequency detection hardware aligned to standard baselines for dependable depth and utility measurements.
Comprehensive diagnostics and rapid-response repair protect underground locating equipment used in rugged field conditions.
Direct technical assistance, consulting and advisory for product operation, troubleshooting and application planning.
Expert training helps operators convert raw detection readings into accurate and actionable underground maps.
Switch categories to preview the relevant workflow for all four main services.
End-to-end support for underground utility detection equipment, from field strategy and operator guidance to precision assurance and long-term asset protection.
Routine calibration keeps multi-frequency detection hardware aligned to standard baselines for dependable depth and utility measurements.
Confirm equipment details, measurement concerns and the required calibration scope.
Test multi-frequency detection performance under controlled reference conditions.
Align hardware against standard baselines and verify background-noise filtering.
Document the completed checks and arrange return of the calibrated equipment.
Comprehensive diagnostics and rapid-response repair protect underground locating equipment used in rugged field conditions.
Register the locator or sensor and document its reported field condition.
Inspect hardware and isolate mechanical, sensor or operating faults.
Complete approved repairs and routine maintenance for specialised locators and sensors.
Confirm operating performance and return the equipment for field deployment.
Advisory and real-time field assistance help teams adapt detection strategy to changing site and environmental conditions.
Assess geology, conductive soil and complex multi-utility corridor conditions.
Recommend suitable detection methods for mapping, diameter calculation and clash avoidance.
Guide operators through sensor-frequency, soil-moisture or software-related issues.
Confirm the field workflow and record the recommended operating adjustments.
Expert training helps operators convert raw detection readings into accurate and actionable underground maps.
Review site goals, user experience and the detection equipment to be deployed.
Guide new and experienced users through practical equipment operation.
Teach teams to interpret complex readings and environmental data signatures.
Apply the workflow to signal loss, difficult ground conditions and equipment-setting adjustments.
Share the product, issue and preferred service date with our support team.
Make Appointment